From Bioblast
O2k-Innovation
- Tyrolean Government grant
- The project O2k-Innovation (officially NextGen-O2k project) was supported by the "Technologiefรถrderungsprogramm - Tiroler Innovationsfรถrderung" of the Tyrolean Government.
- Project duration: 2015-02-01 to 2017-01-31
- Partners in the Oroboros Ecosystem: WGT Elektronik, Software Security Networks
- Application: 2015-01-30; Granted: 2015-03-24 (total budget โฌ 350.000)
- Funding: โฌ 140,000 plus a bonus of โฌ 5,000 for the implementation of gender sensitive actions
O2k-Innovation publication
- Harrison DK, Fasching M, Fontana-Ayoub M, Gnaiger E (2015) Cytochrome redox states and respiratory control in mouse and beef heart mitochondria at steady-state levels of hypoxia. J Appl Physiol Aug 6:jap.00146.2015. doi: 10.1152/japplphysiol.00146.2015. - ยปBioblast linkยซ
The fourth dimension of respiratory control
- On the "line": one dimension is insufficient.
- Coupling and pathway control are two necessarily connected dimensions defining the โareaโ of respiratory control.
- Adding kinetics (including substrate kinetics of O2, CHO, adenylates, Pi, and flux-force kinetics) is the third dimension bringing โvolumeโ into the picture of classical mitochondrial respiratory control.
- The O2k-Innovation on top of O2k-MultiSensor modules and the O2k-FluoRespirometer represent the fourth dimension of respiratory control, by adding analysis of functional variables (such as ROS production, mt-membrane potential, Ca2+, proton flux, cytochrome and NADH redox states, ATP production) to the measurement of O2 and O2-flux in the same chamber.
Development of the O2k-Innovation prototype: a look inside
- Different stages of prototype development: The O2k-Innovation is becoming more and more packed with two spectrofluorometers, two spectrophotometers, light guides, Peltier temperatue control with new heat pipes, microelectronics.
- The NextGen-O2k builds upon and extends the concept of the O2k-Fluorometer elaborated within the K-Regio Project MitoCom O2k-Fluorometer (2011-2014). To broaden the specifications of the O2k-FluoRespirometer, the NextGen-O2k combines high-resolution respirometry with a Q-Module and NADH-Module for RedoxBiology and the PB-Module to study PhotoBiology (including photosynthesis). It is our ultimate goal to further extend the NextGen-O2k with O2k-Spectrofluorometry (including ratiometric measurements), and O2k-Spectrophotometry (allowing for simultaneous measurement of redox states of the cytochromes aa3, b, and c).