Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Horvath 2012 Abstract Bioblast"

From Bioblast
(Created page with "{{Abstract |title=Horvath G (2012) ... Mitochondr Physiol Network 17.12. |info=MiPNet17.12 Bioblast 2012 - Open Access |authors=Horvath G, |year=201...")
 
Line 1: Line 1:
{{Abstract
{{Abstract
|title=Horvath G (2012) ... Mitochondr Physiol Network 17.12.
|title=Horvath G (2012) Respiratory substrates effects on mitochondrial membrane potential, experiments with mouse cardiac muscle homogenate, Mitochondr Physiol Network 17.12.
|info=[[MiPNet17.12 Bioblast 2012|MiPNet17.12 Bioblast 2012 - Open Access]]
|info=[[MiPNet17.12 Bioblast 2012|MiPNet17.12 Bioblast 2012 - Open Access]]
|authors=Horvath G,
|authors=Horvath G,
Line 6: Line 6:
|event=[[Bioblast 2012]]
|event=[[Bioblast 2012]]
|abstract=[[File:Gergö.jpg|right|150px|Gergö Horvath]]
|abstract=[[File:Gergö.jpg|right|150px|Gergö Horvath]]
|keywords=
|mipnetlab=
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|articletype=Abstract
|articletype=Abstract
}}
}}
{{Labeling
{{Labeling
|instruments=
|instruments=Oxygraph-2k, Spectrofluorimetry
|substratestates=
|organism=Mouse
|topics=
|tissues=Cardiac muscle
|preparations=Homogenate
|couplingstates=LEAK, OXPHOS, ETS
|substratestates=CI, CII, CI+II
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|articletype=Abstract
|articletype=Abstract

Revision as of 16:03, 27 November 2012

Horvath G (2012) Respiratory substrates effects on mitochondrial membrane potential, experiments with mouse cardiac muscle homogenate, Mitochondr Physiol Network 17.12.

Link: MiPNet17.12 Bioblast 2012 - Open Access

Horvath G (2012)

Event: Bioblast 2012

Gergö Horvath


Labels:


Organism: Mouse  Tissue;cell: Cardiac muscle"Cardiac muscle" is not in the list (Heart, Skeletal muscle, Nervous system, Liver, Kidney, Lung;gill, Islet cell;pancreas;thymus, Endothelial;epithelial;mesothelial cell, Blood cells, Fat, ...) of allowed values for the "Tissue and cell" property.  Preparation: Homogenate 


Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, Spectrofluorimetry"Spectrofluorimetry" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 




Affiliations and author contributions

Help