Difference between revisions of "Microsyringe\100 mm3 51/0.41 mm"
From Bioblast
Beno Marija (talk | contribs) |
Tindle Lisa (talk | contribs) Β |
||
Line 4: | Line 4: | ||
|abbr= | |abbr= | ||
|description=[[Image:Microsyringe 100 mm3 51 0.41 mm - Kopie.JPG|right|180px]]Hamilton '''Microsyringe\100 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 100 mm<sup>3</sup> volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter. It is recommended for injections of suspensions of isolated mitochondria. | |description=[[Image:Microsyringe 100 mm3 51 0.41 mm - Kopie.JPG|right|180px]]Hamilton '''Microsyringe\100 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 100 mm<sup>3</sup> volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter. It is recommended for injections of suspensions of isolated mitochondria. | ||
|info= [ | |info=[https://www.oroboros.at/index.php/product/microsyringe100-mm3-51-0-41-mm/ '''Product details and purchase information'''] | ||
}} | }} | ||
== Technical support == | == Technical support == | ||
:::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues. | :::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues. | ||
:::* For safe and clean handling, place the syringe in the one of the [https://www.oroboros.at/index.php/product/syringe-racks/ Syringe Racks]. | |||
:::* For safe | :::* Titration of stock solutions into the O2k-Chamber. Β» [[MiPNet09.12 O2k-Titrations]] | ||
:::* [[ | :::* SOP for manual O2k-titrations with Hamilton microsyringes. Β» [[MiPNet19.14 SOP Hamilton microsyringes ]] | ||
Latest revision as of 13:08, 10 November 2020
Microsyringe\100 mm3 51/0.41 mm |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Hamilton Microsyringe\100 mm3 51/0.41 mm for manual titrations, 100 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter. It is recommended for injections of suspensions of isolated mitochondria.
Reference: Product details and purchase information
Technical support
- Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
- For safe and clean handling, place the syringe in the one of the Syringe Racks.
- Titration of stock solutions into the O2k-Chamber. Β» MiPNet09.12 O2k-Titrations
- SOP for manual O2k-titrations with Hamilton microsyringes. Β» MiPNet19.14 SOP Hamilton microsyringes
MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry