Difference between revisions of "Syringe\500 mm3 51/0.41 mm"
From Bioblast
Line 1: | Line 1: | ||
{{Product | {{Product | ||
|description=Hamilton '''Syringe\500 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 500 mm<sup>3</sup> volume; | |description=Hamilton '''Syringe\500 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 500 mm<sup>3</sup> volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the [[Microsyringe\200 mm3\TIP2k]]. | ||
[[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]: 1 included in the [[O2k-Titration Set]]. | [[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]: 1 included in the [[O2k-Titration Set]]. | ||
|product id=51500-01 | |product id=51500-01 | ||
|product type=O2k, TIP2k, Microsyringe, Titration Set | |product type=O2k, TIP2k, Microsyringe, Titration Set | ||
|info=[[O2k-Titration Set]], [[TIP2k-Module]] | |info='''''Β» More details? Consult [[O2k-Titration Set]], [[TIP2k-Module]]''''' | ||
|product image=[[File:Syringe 500 mm3 51 0.41 mm.JPG |right|180px]] | |product image=[[File:Syringe 500 mm3 51 0.41 mm.JPG |right|180px]] | ||
}} | }} | ||
== | == Applications == | ||
* | ::::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues. | ||
*[[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution. | ::::* Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria. | ||
Β | ::::* Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration). | ||
Β | ::::* [[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution. | ||
:: | ::::* For save an clean handling, place the syringe in the one of the [[Syringe Racks]]. | ||
::::* [[MiPNet19.14 SOP Hamilton microsyringes | MiPNet19.14]] - SOP for manual O2k-titrations with Hamilton microsyringes. |
Revision as of 15:46, 2 August 2017
Syringe\500 mm3 51/0.41 mm
Description | Hamilton Syringe\500 mm3 51/0.41 mm for manual titrations, 500 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the Microsyringe\200 mm3\TIP2k.
O2k-FluoRespirometer and Startup O2k-Respirometer: 1 included in the O2k-Titration Set. |
---|---|
Product ID | 51500-01 |
Type | O2k, TIP2k, Microsyringe, Titration Set |
Link | Β» More details? Consult O2k-Titration Set, TIP2k-Module |
Image |
Applications
- Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
- Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
- Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
- TIP2k-Module: gas bubble-free and gas-tight filling of the Microsyringe\200 mm3\TIP2k and the Microsyringe\500 mm3\TIP2k, with a minimum waste of the stock solution.
- For save an clean handling, place the syringe in the one of the Syringe Racks.
- MiPNet19.14 - SOP for manual O2k-titrations with Hamilton microsyringes.