Line 1: Line 1:
{{Product
{{Product
|description=Hamilton '''Syringe\500 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 500 mm<sup>3</sup> volume; injection needle fixed: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the [[Microsyringe\200 mm3\TIP2k]].
|description=Hamilton '''Syringe\500 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 500 mm<sup>3</sup> volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the [[Microsyringe\200 mm3\TIP2k]].


[[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]: 1 included in the [[O2k-Titration Set]].
[[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]: 1 included in the [[O2k-Titration Set]].
|product id=51500-01
|product id=51500-01
|product type=O2k, TIP2k, Microsyringe, Titration Set
|product type=O2k, TIP2k, Microsyringe, Titration Set
|info=[[O2k-Titration Set]], [[TIP2k-Module]]
|info='''''Β» More details? Consult [[O2k-Titration Set]], [[TIP2k-Module]]'''''
|product image=[[File:Syringe 500 mm3 51 0.41 mm.JPG |right|180px]]
|product image=[[File:Syringe 500 mm3 51 0.41 mm.JPG |right|180px]]
|link=
}}
}}
==Uses==
== Applications ==
*Injections of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
::::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
*[[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution.
::::* Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
Β 
::::* Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
Β 
::::* [[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution.
::Β» Go to [[OROBOROS O2k-Catalogue]], [[Purchase]]
::::* For save an clean handling, place the syringe in the one of the [[Syringe Racks]].
::::* [[MiPNet19.14 SOP Hamilton microsyringes | MiPNet19.14]] - SOP for manual O2k-titrations with Hamilton microsyringes.

Revision as of 15:46, 2 August 2017

                



Syringe\500 mm3 51/0.41 mm

O2k-Catalogue

Description Hamilton Syringe\500 mm3 51/0.41 mm for manual titrations, 500 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the Microsyringe\200 mm3\TIP2k.

O2k-FluoRespirometer and Startup O2k-Respirometer: 1 included in the O2k-Titration Set.

Product ID 51500-01
Type O2k, TIP2k, Microsyringe, Titration Set
Link Β» More details? Consult O2k-Titration Set, TIP2k-Module
Image
Syringe 500 mm3 51 0.41 mm.JPG

Applications

  • Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
  • Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
  • Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
  • TIP2k-Module: gas bubble-free and gas-tight filling of the Microsyringe\200 mm3\TIP2k and the Microsyringe\500 mm3\TIP2k, with a minimum waste of the stock solution.
  • For save an clean handling, place the syringe in the one of the Syringe Racks.
  • MiPNet19.14 - SOP for manual O2k-titrations with Hamilton microsyringes.