::::* Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
::::* Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
::::* [[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution.
::::* [[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution.
::::* For save an clean handling, place the syringe in the one of the [[Syringe Racks]].
::::* For safe an clean handling, place the syringe in the one of the [[Syringe Racks]].
::::* [[MiPNet19.14 SOP Hamilton microsyringes | MiPNet19.14]] - SOP for manual O2k-titrations with Hamilton microsyringes.
::::* [[MiPNet19.14 SOP Hamilton microsyringes | MiPNet19.14]] - SOP for manual O2k-titrations with Hamilton microsyringes.

Revision as of 15:51, 2 August 2017

                



Syringe\500 mm3 51/0.41 mm

O2k-Catalogue

Description Hamilton Syringe\500 mm3 51/0.41 mm for manual titrations, 500 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the Microsyringe\200 mm3\TIP2k.

O2k-FluoRespirometer and Startup O2k-Respirometer: 1 included in the O2k-Titration Set.

Product ID 51500-01
Type O2k, TIP2k, Microsyringe, Titration Set
Link Β» More details? Consult O2k-Titration Set, TIP2k-Module
Image
Syringe 500 mm3 51 0.41 mm.JPG

Applications

  • Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
  • Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
  • Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
  • TIP2k-Module: gas bubble-free and gas-tight filling of the Microsyringe\200 mm3\TIP2k and the Microsyringe\500 mm3\TIP2k, with a minimum waste of the stock solution.
  • For safe an clean handling, place the syringe in the one of the Syringe Racks.
  • MiPNet19.14 - SOP for manual O2k-titrations with Hamilton microsyringes.