- ::::ยป[[Potentiometric,pX]]482 bytes (65 words) - 12:29, 24 March 2022
- ...' for H2O2 measurements by fluorometry; rename the potentiometric channel, pX, to TPP+ for mitochondrial membrane measurements with the O2k-pH ISE-Module608 bytes (96 words) - 09:10, 5 April 2022
- ...er (P1, P2, ..) and numbers for O2 sensors, Amp sensors, pX electrodes and pX reference electrodes are entered or edited here. With the [[O2k-FluoRespiro2 KB (276 words) - 10:49, 17 November 2022
- :::::* O2 & pX: Oxygen and potentiometric channel. === Reference Layouts: O2 & pX ===11 KB (1,780 words) - 13:28, 21 March 2022
- ...NC pX plug for the ion sensitive electrode, ISE; and separate plug for the pX reference electrode, Ref). :::: 3a. pX channel - [[O2k-TPP+ ISE-Module]]: Output type III.6 KB (873 words) - 07:12, 29 March 2024
- ...hich plots should be selected.(Oxygen O2, Amperometric Amp, Potentiometric pX, System channels) :::# '''Channel label'''Edit (for Amp and pX channels).5 KB (769 words) - 15:28, 11 April 2018
- ...n modules |O2k signal]]: The [[O2k-pH ISE-Module]] is operated through the pX channel of the O2k, with electric potential (volt [V]) as the primary and r ...roboros O2k]] supports the modular O2k-MultiSensor extension for recording potentiometric (voltage) signals simultaneously with the oxygen signals in both O2k-chambe37 KB (5,713 words) - 12:13, 28 February 2023
- ...e potential in biological samples (isolated mitochondria, homogenate) with potentiometric (O2k-TPP+ ISE-Module) and fluorescence method (TMRM, safranin/O2k-Fluo LED2 |Determination of mt-membrane potential with potentiometric O2k-TPP+ ISE-Module - an introduction.10 KB (1,320 words) - 15:42, 8 June 2020
- ...b>2</sub>O measurements by fluorometry; rename the potentiometric channel, pX, to TPP+ for mitochondrial membrane measurements with the O2k-pH ISE-Module10 KB (1,339 words) - 09:33, 6 May 2021
- ...modules |O2k signal]]: The [[O2k-TPP+ ISE-Module]] is operated through the pX channel of the O2k, with electric potential (volt [V]) as the primary and r ...to the "calibrated" chamber. Therefore, unlike in the application of other potentiometric methods (pH, Ca<sup>2+</sup>,..) the "calibration" does in fact serve two d37 KB (5,710 words) - 15:30, 16 May 2023
- ...potentiometric channel, however, is primarily expressed logarithmically as pX=-log(''c''<sub>X</sub>/''c''ยฐ) and then transformed to ''c<sub>X</sub>''.17 KB (2,751 words) - 09:55, 17 November 2023
- '''O2k-potentiometric measurement of mt-membrane potential with TPP<sup>+</sup>''': TPP<sup>+</su :::: [[File:Sponsors.png| 750 px]]14 KB (1,894 words) - 15:21, 8 June 2020