Difference between revisions of "Automatic pan - DatLab"
(added technical support banner) ย |
|||
(5 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{MitoPedia | {{Technical support}} | ||
|description='''Automatic pan''' (only for real-time data recording) toggles automatic panning on/off by clicking in the [[O2k status line]]. If it is on (green), the time range is maintained while the time axis always shows the currently recorded data, i.e. the value of the offset (minimum value) increases as experimental time proceeds. If it is off (yellow), the time axis is static | {{MitoPedia without banner | ||
|info= | |description='''Automatic pan''' (only for real-time data recording) toggles automatic panning on/off by clicking in the [[O2k status line]]. If it is on (green), the time range is maintained while the time axis always shows the currently recorded data, i.e. the value of the offset (minimum value) increases as experimental time proceeds. If it is off (yellow), the time axis is static. This allows for manually panning backwards to observe previous sections of the experimentย at a given time range.ย In this mode, the actual experimental time may be off-scale. Toggle between "Pan auto" and "Pan off" by a left-click on the text. It does not influence continuous data recording. It is recommended to maintain automatic panning on during the experiment, except for specifically viewing earlier sections of the experiment. | ||
|info= | |||
}} | }} | ||
{{MitoPedia O2k and high-resolution respirometry | {{MitoPedia O2k and high-resolution respirometry | ||
|mitopedia O2k and high-resolution respirometry=DatLab | |mitopedia O2k and high-resolution respirometry=DatLab | ||
}} | }} |
Latest revision as of 11:22, 25 March 2022
Automatic pan - DatLab |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Automatic pan (only for real-time data recording) toggles automatic panning on/off by clicking in the O2k status line. If it is on (green), the time range is maintained while the time axis always shows the currently recorded data, i.e. the value of the offset (minimum value) increases as experimental time proceeds. If it is off (yellow), the time axis is static. This allows for manually panning backwards to observe previous sections of the experiment at a given time range. In this mode, the actual experimental time may be off-scale. Toggle between "Pan auto" and "Pan off" by a left-click on the text. It does not influence continuous data recording. It is recommended to maintain automatic panning on during the experiment, except for specifically viewing earlier sections of the experiment.
MitoPedia O2k and high-resolution respirometry:
DatLab