Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Cyanide"

From Bioblast
(added Template:Chemical_description)
 
(14 intermediate revisions by 2 users not shown)
Line 17: Line 17:
::::* [[alternative oxidase]]
::::* [[alternative oxidase]]


:::: <span style="color:#8B008B"> '''Caution:''' Due to a confusion, a change in the procedure for preparing the KCN was done in April 2019 that recommended to prepare 20 mM KCN stock and titrate 100 µl. This now have been corrected to our previous recommendation of 1 M KCN stock solutions </span>
::: '''O2k manual titrations'''  [[MiPNet09.12 O2k-Titrations]]
::::* Titration volume: 2 µl of 1 M stock, using a 10 µl syringe (2 ml O2k-chamber).
::::* Final concentration: 1 mM.


=== Preparation of 1 M KCN stock ===
=== Preparation of KCN stock ===
{{Chemical_description
|abbr=KCN
|trivial name=Cyanide
|complete name=Potassium cyanide
|chem formula=KCN
|molar mass=65.12
|vendor=Sigma-Aldrich
|product number=60178
|store at=RT
|sensitivity=
|cas=151-50-8
|h statements=H290, H300, H330, H310, H372, H400, H410
|h info=may be corrosive to metals, fatal if swallowed, fatal if inhaled, fatal in contact with skin, causes damage to organs through prolonged or repeated exposure (thyroid), very toxic to aquatic life, very toxic to aquatic life with long-lasting effects
}}<!--:::: '''Kcn'''(KCN): Sigma 60178, 100 g, store at R.T.; M = 65.12 g·mol<sup>-1</sup>.-->
:::: <span style="color:#8B008B"> '''Caution:''' Very toxic! Protect from light, store in a cool, dry, well-ventilated location. Separate from water, acids, and carbon dioxide. For details refer to [https://pubchem.ncbi.nlm.nih.gov/compound/9032#section=Storage-Conditions PubChem]</span>
:::: '''Caution:''' In April 2019 a change in the procedure for preparing the KCN was done that recommended to prepare 20 mM KCN stock and titrate 100 µL. 2021-01-22: after discussions on KCN toxicity we recommend to prepare of 0.5 M KCN stock solutions.


:::: '''Kcn'''(KCN): Fluka 60178, 100 g, store at R.T.; FW = 65.12.


:::: <span style="color:#8B008B"> '''Caution:''' KCN is photosensitive and hygroscopic; KCN is volatile and very toxic! </span>
:::: ''' Preparation of 0.5 M KCN stock solution''' (dissolved in H<sub>2</sub>O):
:::: ''' Preparation of 1 M KCN stock solution ''' for '''2-mL O2k-chamber'''


::::# Weigh 13 mg of KCN.  
::::# Weigh 32.6 mg of KCN.  
 
::::# Dissolve in 1 ml H<sub>2</sub>O.
::::# Dissolve in 0.2 ml H<sub>2</sub>O.
::::# The pH of the solution is basic. Since the titration amount is low and HCN may evaporate during pH adjustment with HCl, the pH is not adjusted.
::::# The pH of the solution may be very alkaline - adjust to physiological pH with HCl.
::::# Divide into 0.2 mL portions
          :::» '''O2k manual titrations'''  [[MiPNet09.12 O2k-Titrations]]
::::# Store at -20 °C.
::::* Titration volume ('''2-mL O2k-chamber'''): 100 µL using a 100 µL Hamilton syringe.


:::» '''O2k manual titrations'''  [[MiPNet09.12 O2k-Titrations]]
::::* Titration volume ('''2-mL O2k-chamber'''): 4 µL using a 10 µL Hamilton syringe.
::::* Titration volume ('''0.5-mL O2k-chamber'''): 1 µL using a 10 µL Hamilton syringe.
::::* Final concentration: 1 mM.
::::* Final concentration: 1 mM.


:::: '''Preparation of 250 mM KCN stock solution''' (in 45 mM Trizma base) for '''0.5-mL O2k-chamber''':
::::# Weigh 16,28 mg of KCN and dissolve in 1 mL of 45 mM Trizma base.
::::# Divide into 200 µL aliquots (use dark glass vials).
::::# Store frozen at -20 °C.
:::» '''O2k manual titrations'''  [[MiPNet09.12 O2k-Titrations]]
::::* Titration volume ('''0.5-mL O2k-chamber'''): 2 µL using a 10 µL Hamilton syringe.
::::* Final concentration: 1 mM.
{{MitoPedia O2k and high-resolution respirometry|type=Inhibitor ETS
{{MitoPedia O2k and high-resolution respirometry|type=Inhibitor ETS
}}
}}

Latest revision as of 09:51, 10 June 2021


high-resolution terminology - matching measurements at high-resolution


Cyanide

Description

Cyanide (usually added as KCN) is a competitive inhibitor of cytochcrome c oxidase (CIV). Inhibition is reversed by pyruvate and high oxygen levels.

Abbreviation: KCN

Reference: MiPNet09.12



MitoPedia topics: Inhibitor 

Application in HRR

Inhibitor titrations, CIV-assay, alternative oxidase and ROX


Preparation of KCN stock

KCN: Cyanide (Potassium cyanide; KCN), Sigma-Aldrich: 60178, store at RT, CAS: 151-50-8, M = 65.12 g·mol-1
Hazard statements: H290, H300, H330, H310, H372, H400, H410; may be corrosive to metals, fatal if swallowed, fatal if inhaled, fatal in contact with skin, causes damage to organs through prolonged or repeated exposure (thyroid), very toxic to aquatic life, very toxic to aquatic life with long-lasting effects
Caution: Very toxic! Protect from light, store in a cool, dry, well-ventilated location. Separate from water, acids, and carbon dioxide. For details refer to PubChem
Caution: In April 2019 a change in the procedure for preparing the KCN was done that recommended to prepare 20 mM KCN stock and titrate 100 µL. 2021-01-22: after discussions on KCN toxicity we recommend to prepare of 0.5 M KCN stock solutions.


Preparation of 0.5 M KCN stock solution (dissolved in H2O):
  1. Weigh 32.6 mg of KCN.
  2. Dissolve in 1 ml H2O.
  3. The pH of the solution is basic. Since the titration amount is low and HCN may evaporate during pH adjustment with HCl, the pH is not adjusted.
  4. Divide into 0.2 mL portions
  5. Store at -20 °C.
» O2k manual titrations MiPNet09.12 O2k-Titrations
  • Titration volume (2-mL O2k-chamber): 4 µL using a 10 µL Hamilton syringe.
  • Titration volume (0.5-mL O2k-chamber): 1 µL using a 10 µL Hamilton syringe.
  • Final concentration: 1 mM.



MitoPedia topics: Inhibitor