L/E coupling-control ratio: Difference between revisions

From Bioblast
No edit summary
No edit summary
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=''L/E''
|abbr=''L/E''
|description=The '''LEAK control ratio''' is an index of [[uncoupling]] or [[dyscoupling]] at constant [[ETS capacity]].  ''L/E'' increases with [[uncoupling]] from a theoretical minimum of 0.0 for a fully coupled system, to 1.0 for a fully uncoupled system.
|description=The '''LEAK control ratio''' is an index of [[uncoupling]] or [[dyscoupling]] at constant [[ETS capacity]].  ''L/E'' increases with [[uncoupling]] from a theoretical minimum of 0.0 for a fully coupled system, to 1.0 for a fully uncoupled ([[non-coupled]] system.
See also [[LEAK state]].
See also [[LEAK state]].
|info=[[MiPNet12.15]]; [[Gnaiger_2009_IJBCB]]
|info=[[MiPNet12.15]]; [[Gnaiger_2009_IJBCB]]
Line 9: Line 9:
|discipline=Mitochondrial Physiology
|discipline=Mitochondrial Physiology
|topics=Respiration; OXPHOS; ETS Capacity, Flux Control; Additivity; Threshold; Excess Capacity, Coupling; Membrane Potential
|topics=Respiration; OXPHOS; ETS Capacity, Flux Control; Additivity; Threshold; Excess Capacity, Coupling; Membrane Potential
|type=Respiration
}}
}}

Revision as of 08:17, 19 October 2010


high-resolution terminology - matching measurements at high-resolution


L/E coupling-control ratio

Description

The LEAK control ratio is an index of uncoupling or dyscoupling at constant ETS capacity. L/E increases with uncoupling from a theoretical minimum of 0.0 for a fully coupled system, to 1.0 for a fully uncoupled (non-coupled system. See also LEAK state.

Abbreviation: L/E

Reference: MiPNet12.15; Gnaiger_2009_IJBCB


Labels:




Regulation: Respiration; OXPHOS; ETS Capacity"Respiration; OXPHOS; ETS Capacity" is not in the list (Aerobic glycolysis, ADP, ATP, ATP production, AMP, Calcium, Coupling efficiency;uncoupling, Cyt c, Flux control, Inhibitor, ...) of allowed values for the "Respiration and regulation" property., Flux Control; Additivity; Threshold; Excess Capacity"Flux Control; Additivity; Threshold; Excess Capacity" is not in the list (Aerobic glycolysis, ADP, ATP, ATP production, AMP, Calcium, Coupling efficiency;uncoupling, Cyt c, Flux control, Inhibitor, ...) of allowed values for the "Respiration and regulation" property., Coupling; Membrane Potential"Coupling; Membrane Potential" is not in the list (Aerobic glycolysis, ADP, ATP, ATP production, AMP, Calcium, Coupling efficiency;uncoupling, Cyt c, Flux control, Inhibitor, ...) of allowed values for the "Respiration and regulation" property. 




Cookies help us deliver our services. By using our services, you agree to our use of cookies.