|abstract=The PBI-Shredder HRR-Set is an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues with high reproducibility of mitochondrial yield and mitochondrial function. In this manual for applications with high-resolution respirometry (HRR), we refer to the PBI User Manual with safety information, product use limitations and warranty information, and the Product Specification Sheet by Pressure BioSciences Inc. (PBI). | |abstract=The PBI-Shredder HRR-Set is an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues with high reproducibility of mitochondrial yield and mitochondrial function. In this manual for applications with high-resolution respirometry (HRR), we refer to the PBI User Manual with safety information, product use limitations and warranty information, and the Product Specification Sheet by Pressure BioSciences Inc. (PBI). | ||
|keywords=Tissue homogenate, shredder | |keywords=Tissue homogenate, shredder | ||
|mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E | |mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |articletype=Protocol; Manual, MiPNet-online Publication | ||
}} | }} | ||
Line 16: | Line 16: | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |articletype=Protocol; Manual, MiPNet-online Publication | ||
}} | }} | ||
[[Category:OroboPedia]] | [[Category:OroboPedia]] |
Revision as of 14:37, 7 December 2012
Draxl A, Eigentler A, Gnaiger E. PBI-Shredder HRR-Set: Preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. Mitochondr Physiol Network 17.02. |
ยป MiPNet17.02. Open Access, PBI-Shredder HRR-Set
Draxl A, Eigentler A, Gnaiger E (
Abstract: The PBI-Shredder HRR-Set is an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues with high reproducibility of mitochondrial yield and mitochondrial function. In this manual for applications with high-resolution respirometry (HRR), we refer to the PBI User Manual with safety information, product use limitations and warranty information, and the Product Specification Sheet by Pressure BioSciences Inc. (PBI). โข Keywords: Tissue homogenate, shredder
โข O2k-Network Lab: AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom
Labels:
Preparation: Homogenate
HRR: Oxygraph-2k, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
mt-Preparation