{{Product | {{Product | ||
|description='''O2k-NO Amp-Module''': 2 [[Stopper\black PEEK\conical Shaft\central Port\peripheral 2.3 mm Port|black PEEK stoppers]] for amperometric O2k-MultiSensor application (NO, H2S, H2O2); 1 additional hole (2.3 mm); central titration port; conical bottom; with [[Volume-Calibration Ring]]s (A and B); with 16 spare O-rings ([[O-ring\Viton\12.5x1 mm]]; two boxes). The NO sensor is not included. | |description='''O2k-NO Amp-Module''': 2 [[Stopper\black PEEK\conical Shaft\central Port\peripheral 2.3 mm Port|black PEEK stoppers]] for amperometric O2k-MultiSensor application (NO, H2S, H2O2); 1 additional hole (2.3 mm); central titration port; conical bottom; with [[Volume-Calibration Ring]]s (A and B); 2 O-rings mounted on each stopper, with 16 spare O-rings ([[O-ring\Viton\12.5x1 mm]]; two boxes). The NO sensor is not included. | ||
|product id=12500-02 | |product id=12500-02 | ||
|product type=O2k, O2k-Module, MultiSensor, O2k-NO Amp-Module, Stopper | |product type=O2k, O2k-Module, MultiSensor, O2k-NO Amp-Module, Stopper |
Revision as of 12:14, 15 July 2019
O2k-NO Amp-Module
Description | O2k-NO Amp-Module: 2 black PEEK stoppers for amperometric O2k-MultiSensor application (NO, H2S, H2O2); 1 additional hole (2.3 mm); central titration port; conical bottom; with Volume-Calibration Rings (A and B); 2 O-rings mounted on each stopper, with 16 spare O-rings (O-ring\Viton\12.5x1 mm; two boxes). The NO sensor is not included. |
---|---|
Product ID | 12500-02 |
Type | O2k, O2k-Module, MultiSensor, O2k-NO Amp-Module, Stopper |
Link | MiPNet15.05 NO-manual, MiPNet08.12 IOC22 |
Image |
MitoPedia O2k and high-resolution respirometry:
O2k hardware
Amp-Sensors
- We are developing improved high-resolution sensors. The NO Sensor is not yet included in the purchase of this module. Sensors are available from World Precision Instruments (WPI). Oroboros Instruments provides this information without comment or liability with regards to the material quality, or the suitability of these sensors for any particular application.
- The Oroboros O2k (Series E upwards) is fully equipped with the necessary electronics to record signals from additional amperometric sensors. O2k-Multisensor options of O2k Series A to D are explained in the O2k-Manual (MiPNet15.05 NO-manual).
- NO and other amperometric sensors from WPI: The O2k amperometric plug fully matches the WPI 2 mm sensor series for measuring NO (ISO-NOP), H2O2 (ISO-HPO-2) and H2S (ISO-H2S-2). These sensors are equipped with membranes of different thickness. The O2k stopper as listed above accommodates all three types.
- Oroboros Instruments does not offer and deliver products from WPI. The restricted warranty period offered by WPI is incompatible with our high standard of user support.