{{Product | {{Product | ||
|description=The '''O2k-Titration Set''' consists of Hamilton microsyringes (6 x 10 mm<sup>3</sup> and 3 spare plungers, 6 x 25 mm<sup>3</sup>, 1 x 50 mm<sup>3</sup>, 1 x 100 mm<sup>3</sup>, 1 x 500 mm<sup>3</sup>; fixed needles with rounded tips), provided in the [[Syringe Storage Box]] with [[Syringe Labels]], a set of two [[Syringe Racks]] with [[Syringe Collars]], and a set of two [[Tube Racks]]. Β | |description=[[Image:O2k-Titration Set.JPG|right|180px]] The '''O2k-Titration Set''' consists of Hamilton microsyringes (6 x 10 mm<sup>3</sup> and 3 spare plungers, 6 x 25 mm<sup>3</sup>, 1 x 50 mm<sup>3</sup>, 1 x 100 mm<sup>3</sup>, 1 x 500 mm<sup>3</sup>; fixed needles with rounded tips), provided in the [[Syringe Storage Box]] with [[Syringe Labels]], a set of two [[Syringe Racks]] with [[Syringe Collars]], and a set of two [[Tube Racks]]. Β | ||
The O2k-Titration Set is included in the [[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]. | The O2k-Titration Set is included in the [[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]. | ||
|product id=20820-03 | |product id=20820-03 | ||
|product type=O2k, Microsyringe, O2k-FluoRespirometer, Startup O2k-Respirometer | |product type=O2k, Microsyringe, O2k-FluoRespirometer, Startup O2k-Respirometer | ||
|info=[ | |info= [https://www.oroboros.at/index.php/product/o2k-titration-set/ '''Product details and purchasing information'''] | ||
|product image= | |product image= | ||
Β | |||
}} | }} | ||
== | == Additional resources == | ||
Β»[[MiPNet09.12 O2k-Titrations]] | |||
Β | |||
[[ | Β»[[MiPNet19.14 SOP Hamilton microsyringes]] | ||
== Note: Titration of chemicals in respirometry == | == Note: Titration of chemicals in respirometry == | ||
Line 38: | Line 19: | ||
=== Further information === | === Further information === | ||
:::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues. | :::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues. | ||
:::* Hamilton microsyringes are specifically produced for O2k-titrations and can be ordered directly from Oroboros Instruments to assure exact fitting with the O2k-Stopper and O2k-Chamber dimensions. | :::* Hamilton microsyringes are specifically produced for O2k-titrations and can be ordered directly from Oroboros Instruments to assure exact fitting with the O2k-Stopper and O2k-Chamber dimensions. | ||
:::* Visit also: [http://www.hamiltoncompany.com/products/syringes-and-needles Hamilton]. | :::* Visit also: [http://www.hamiltoncompany.com/products/syringes-and-needles Hamilton]. | ||
:::* Eliminate | :::* Eliminate rough edges with 3Mβ’ Wetordryβ’ Paper Sheet P1000 by gentle rubbing. | ||
:::* Use a cleaning wire for the needle. If a syringe is | :::* Use a cleaning wire for the needle. If a syringe is clogged , sometimes it is also helpful to fill it from the back with EtOH or H<sub>2</sub>O and try to press the plunger gently down. |
Revision as of 09:58, 18 February 2020
O2k-Titration Set
Description | The O2k-Titration Set consists of Hamilton microsyringes (6 x 10 mm3 and 3 spare plungers, 6 x 25 mm3, 1 x 50 mm3, 1 x 100 mm3, 1 x 500 mm3; fixed needles with rounded tips), provided in the Syringe Storage Box with Syringe Labels, a set of two Syringe Racks with Syringe Collars, and a set of two Tube Racks.
The O2k-Titration Set is included in the O2k-FluoRespirometer and Startup O2k-Respirometer. |
---|---|
Product ID | 20820-03 |
Type | O2k, Microsyringe, O2k-FluoRespirometer, Startup O2k-Respirometer |
Link | Product details and purchasing information |
Image |
Additional resources
Β»MiPNet19.14 SOP Hamilton microsyringes
Note: Titration of chemicals in respirometry
- Overshoots or short interruptions of the flux after the injection of chemicals do not have a meaning in respirometric measurements. A disturbance of the signal is only observed due to the injected chemical and does not represent mitochondrial respiration. With the addition of a chemical solved in ethanol a little bit of oxygen is always introduced, since ethanol has higher oxygen solubility than water.
Further information
- Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
- Hamilton microsyringes are specifically produced for O2k-titrations and can be ordered directly from Oroboros Instruments to assure exact fitting with the O2k-Stopper and O2k-Chamber dimensions.
- Visit also: Hamilton.
- Eliminate rough edges with 3Mβ’ Wetordryβ’ Paper Sheet P1000 by gentle rubbing.
- Use a cleaning wire for the needle. If a syringe is clogged , sometimes it is also helpful to fill it from the back with EtOH or H2O and try to press the plunger gently down.