(Created page with "{{OROBOROS_header_page_name}} :::: <big>'''OROBOROS Oxygraph-2k - unique for high-resolution respirometry (HRR)'''</big> ::::::::::: <big>'''O2k - tested and tru...")
 
Line 2: Line 2:
:::: <big>'''[[Oxygraph-2k |OROBOROS Oxygraph-2k]] - unique for high-resolution respirometry (HRR)'''</big>
:::: <big>'''[[Oxygraph-2k |OROBOROS Oxygraph-2k]] - unique for high-resolution respirometry (HRR)'''</big>
::::::::::: <big>'''O2k - tested and trusted'''</big>
::::::::::: <big>'''O2k - tested and trusted'''</big>
[[Image:Oxygraph-2k-Concept.jpg|right|300px |O2k-Concept.jpg]]
[[Image:Oxygraph-2k-Concept.jpg|right|300px|link=O2k high-resolution respirometry |HRR]]


== The O2k for high-resolution respirometry ==
== The O2k for high-resolution respirometry ==
[[Image:O2k-Fluorometer.JPG|120px|left|link=http://wiki.oroboros.at/index.php/O2k-Fluorometer|O2k-Fluorometer]]  
[[Image:O2k-Fluorometer.JPG|left|120px|link=http://wiki.oroboros.at/index.php/Oxygraph-2k |O2k]]  
The OROBOROS Oxygraph-2k provides a unique high-resolution approach for the monitoring of cellular and mitochondrial respiratory function. [[High-resolution respirometry]] is indispensable at low respiratory activities, kinetic transitions and low oxygen levels. Such high resolution is required in particular for the analysis of pathological effects resulting in reduced respiration (mitochondrial and metabolic diseases, ischemia-reperfusion injury, oxidative stress, apoptosis, aging); biopsies with limited amounts of sample (diagnosis of genetic and acquired mitochondrial defects in pediatric patients, diabetes); cell cultures with limited cell numbers or low activities; mutants with diminished respiratory capacity; chemical oxidation rates and antioxidant capacities; and respiratory measurements at low, physiological intracellular oxygen levels and oxygen kinetics.


The OROBOROS Oxygraph-2k provides a unique high-resolution approach for the monitoring of cellular and mitochondrial respiratory function: [[high-resolution respirometry |high-resolution respirometry (HRR)]]. Considering mitochondria as the powerhouses of the cell, HRR introduced the concept of [[cell ergometry]]. Are your cells [[MitoFit]]? HRR is now applied world-wide for the analysis of mitochondrial and metabolic diseases, in the rapidly growing field of  ischemia-reperfusion injury, oxidative stress, apoptosis, aging); biopsies with limited amounts of sample (diagnosis of genetic and acquired mitochondrial defects in pediatric patients, diabetes); cell cultures with limited cell numbers or low activities; mutants with diminished respiratory capacity; chemical oxidation rates and antioxidant capacities; and respiratory measurements at low, physiological intracellular oxygen levels and oxygen kinetics.


[[Image:Logo_OROBOROS_INSTRUMENTS.jpg|left|120px|link=http://wiki.oroboros.at/index.php/OROBOROS_INSTRUMENTS |OROBOROS]]
 
[[File:OROBOROS MitoFit-Lab.jpg|left|240px|link=http://wiki.oroboros.at/index.php/OROBOROS_INSTRUMENTS |OROBOROS]]
[[File:OROBOROS-Concept.jpg|right|300px|link=OROBOROS Company]]
[[File:OROBOROS-Concept.jpg|right|300px|link=OROBOROS Company]]
High-resolution respirometry by the OROBOROS O2k is based on a radically different systems approach to polarographic measurement of oxygen dynamics. High-resolution respirometry rests on several tightly connected instrumental features and concepts integrated by the DatLab software, providing on-line display of oxygen concentration and respiration ([[oxygen flux]]). The mechanics, critical selection of materials, and state-of-the-art electronics provide the basis of signal stability of an optimized [[polarographic oxygen sensor]], in an electronically controlled thermal environment with high temperature stability. Calibrations and instrumental controls follow standardized procedures, with highly automatic on-line analysis by the DatLab software. Scientific support is complementary to the approach of high-resolution respirometry.
High-resolution respirometry by the OROBOROS O2k is based on a radically different systems approach to polarographic measurement of oxygen dynamics. High-resolution respirometry rests on several tightly connected instrumental features and concepts integrated by the DatLab software, providing on-line display of oxygen concentration and respiration ([[oxygen flux]]). The mechanics, critical selection of materials, and state-of-the-art electronics provide the basis of signal stability of an optimized [[polarographic oxygen sensor]], in an electronically controlled thermal environment with high temperature stability. Calibrations and instrumental controls follow standardized procedures, with highly automatic on-line analysis by the DatLab software. Scientific support is complementary to the approach of high-resolution respirometry.


While the OROBOROS O2k provides the instrumental basis for high-resolution respirometry, successful operation at high accuracy up to the limit of detection depends on a professional application by the technician, scientist or student. Participation in a hands-on introductory [[O2k-Workshop]] is recommended to save time and gain from the experience obtained over many years of application in various settings.
[[Image:The world as a laboratory.jpg|left|120px|link=http://wiki.oroboros.at/index.php/The_world_as_a_laboratory |The world as a laboratory]]
While the OROBOROS O2k provides the instrumental basis for high-resolution respirometry, successful operation at high accuracy up to the limit of detection depends on a professional application by the technician, scientist or student. Participation in a hands-on introductory [[O2k-Workshop]] is recommended to save time and gain from the experience obtained over many years of application in various [[The world as a laboratory |settings]].
 


== From the O2k to the Power-O2k ==
== From the O2k to the Power-O2k ==
[[Image:Power-O2k.png|left|120px|link=http://wiki.oroboros.at/index.php/Power-O2k|Power-O2k]]
Multiple O2k-units are offered as a ‘Power-O2k System’ for high-resolution respirometry combined with high-throughput - at high output.
Multiple O2k-units are offered as a ‘Power-O2k System’ for high-resolution respirometry combined with high-throughput - at high output.


:: ''More details? Consult'' [[Power-O2k]]
:: ''More details? Consult'' [[Power-O2k]]

Revision as of 05:47, 8 January 2016

                



O2k and HRR

OROBOROS Oxygraph-2k - unique for high-resolution respirometry (HRR)
O2k - tested and trusted
HRR

The O2k for high-resolution respirometry

O2k

The OROBOROS Oxygraph-2k provides a unique high-resolution approach for the monitoring of cellular and mitochondrial respiratory function: high-resolution respirometry (HRR). Considering mitochondria as the powerhouses of the cell, HRR introduced the concept of cell ergometry. Are your cells MitoFit? HRR is now applied world-wide for the analysis of mitochondrial and metabolic diseases, in the rapidly growing field of ischemia-reperfusion injury, oxidative stress, apoptosis, aging); biopsies with limited amounts of sample (diagnosis of genetic and acquired mitochondrial defects in pediatric patients, diabetes); cell cultures with limited cell numbers or low activities; mutants with diminished respiratory capacity; chemical oxidation rates and antioxidant capacities; and respiratory measurements at low, physiological intracellular oxygen levels and oxygen kinetics.


OROBOROS
Oroboros Ecosystem.jpg

High-resolution respirometry by the OROBOROS O2k is based on a radically different systems approach to polarographic measurement of oxygen dynamics. High-resolution respirometry rests on several tightly connected instrumental features and concepts integrated by the DatLab software, providing on-line display of oxygen concentration and respiration (oxygen flux). The mechanics, critical selection of materials, and state-of-the-art electronics provide the basis of signal stability of an optimized polarographic oxygen sensor, in an electronically controlled thermal environment with high temperature stability. Calibrations and instrumental controls follow standardized procedures, with highly automatic on-line analysis by the DatLab software. Scientific support is complementary to the approach of high-resolution respirometry.

The world as a laboratory

While the OROBOROS O2k provides the instrumental basis for high-resolution respirometry, successful operation at high accuracy up to the limit of detection depends on a professional application by the technician, scientist or student. Participation in a hands-on introductory O2k-Workshop is recommended to save time and gain from the experience obtained over many years of application in various settings.


From the O2k to the Power-O2k

Power-O2k

Multiple O2k-units are offered as a ‘Power-O2k System’ for high-resolution respirometry combined with high-throughput - at high output.

More details? Consult Power-O2k