SUIT-009 O2 ce-pce D016: Difference between revisions

From Bioblast
No edit summary
No edit summary
Line 18: Line 18:


== 1S;2D;3P;4Rot;5Ama-==
== 1S;2D;3P;4Rot;5Ama-==
SUIT 9 is a short protocol for simultaneous determination of O<sub>2</sub> flux and the rate of [[MiPNet20.14 AmplexRed H2O2-production|H<sub>2</sub>O<sub>2</sub> production]] (H<sub>2</sub>O<sub>2</sub> flux) on isolated mitochondria,tissue homogenate (except of liver) and permeabilized cells. Succinate (S) supports the reverse electron transfer (RET) initiated H<sub>2</sub>O<sub>2</sub> production in the LEAK state. Addition of ADP decreases H<sub>2</sub>O<sub>2</sub> flux due to depolarization of the mitochondrial membrane. Pyruvate (P) supports [[NADH Electron transfer-pathway state|NADH-pathway (N)]], and usually in the presence of ADP it does not increase further the H<sub>2</sub>O<sub>2</sub> flux. Antimycin A (Ama) inhibits Complex III (CIII) and results in the elevation of the H<sub>2</sub>O<sub>2</sub> flux. The sensitivity of the Amplex UltraRedยฎ assay (for determining H<sub>2</sub>O<sub>2</sub> production) is changing over the experimental time and upon addition of chemicals. To correct H<sub>2</sub>O<sub>2</sub> flux for the sensitivity changes several [[MiPNet20.14_AmplexRed_H2O2-production#Calibration_with_H2O2|H<sub>2</sub>O<sub>2</sub> calibration steps]] are done during the experiment. The measurement is carried out in MiR05-Kit at 37 ยฐC. ย 
SUIT 9 is a short protocol for simultaneous determination of O<sub>2</sub> flux and the rate of [[MiPNet20.14 AmplexRed H2O2-production|H<sub>2</sub>O<sub>2</sub> production]] (H<sub>2</sub>O<sub>2</sub> flux) on isolated mitochondria,tissue homogenate (except of liver) and permeabilized cells. Succinate (S) supports the reverse electron transfer (RET) initiated H<sub>2</sub>O<sub>2</sub> production in the LEAK state. Addition of ADP decreases H<sub>2</sub>O<sub>2</sub> flux due to depolarization of the mitochondrial membrane. Pyruvate (P) supports [[NADH Electron transfer-pathway state|NADH-pathway (N)]], and usually in the presence of ADP it does not increase further the H<sub>2</sub>O<sub>2</sub> flux. Antimycin A (Ama) inhibits Complex III (CIII) and results in the elevation of the H<sub>2</sub>O<sub>2</sub> flux. The sensitivity of the Amplex UltraRedยฎ assay (for determining H<sub>2</sub>O<sub>2</sub> production) is changing over the experimental time and upon addition of chemicals. To correct H<sub>2</sub>O<sub>2</sub> flux for the sensitivity changes several [[MiPNet20.14_AmplexRed_H2O2-production#Calibration_with_H2O2|H<sub>2</sub>O<sub>2</sub> calibration steps]] are done during the experiment. The measurement is carried out in MiR05-Kit at 37 ยฐC.
ย 
== SUIT O2 DLP for SUIT 9 (DatLab 7.3) ==
ย 
''Updating this page (2018-06-13) for DatLab 7.3 DLP files''

Revision as of 15:41, 7 November 2018


high-resolution terminology - matching measurements at high-resolution


SUIT-009 O2 ce-pce D016

Description

SUIT9

Abbreviation: NS(P)

Reference: A: SUIT 9 is a short SUIT protocol for H2O2 (AmR) in permeabilized cells.

SUIT number: D16_ce1;1Dig;1S;2D;3P;4Rot;5Ama

O2k-Application: O2


MitoPedia concepts: SUIT protocol, SUIT A 

SUIT-category: NS(P)




1S;2D;3P;4Rot;5Ama-

SUIT 9 is a short protocol for simultaneous determination of O2 flux and the rate of H2O2 production (H2O2 flux) on isolated mitochondria,tissue homogenate (except of liver) and permeabilized cells. Succinate (S) supports the reverse electron transfer (RET) initiated H2O2 production in the LEAK state. Addition of ADP decreases H2O2 flux due to depolarization of the mitochondrial membrane. Pyruvate (P) supports NADH-pathway (N), and usually in the presence of ADP it does not increase further the H2O2 flux. Antimycin A (Ama) inhibits Complex III (CIII) and results in the elevation of the H2O2 flux. The sensitivity of the Amplex UltraRedยฎ assay (for determining H2O2 production) is changing over the experimental time and upon addition of chemicals. To correct H2O2 flux for the sensitivity changes several H2O2 calibration steps are done during the experiment. The measurement is carried out in MiR05-Kit at 37 ยฐC.

Cookies help us deliver our services. By using our services, you agree to our use of cookies.