Startup O2k-Respirometer: Difference between revisions
From Bioblast
(Created page with "{{MitoPedia |abbr=O2k-Core |description=The '''Oxygraph-2k Core''' System for HRR. |info=Oxygraph-2k Core }} {{MitoPedia methods |mitoped...") |
m (moved Oxygraph-2k Core to Oxygraph-2k) |
||
Line 1: | Line 1: | ||
{{ | {{Product | ||
|description='''OROBOROS Oxygraph-2k Core''' (O2k-Core) is the complete experimental system for [[high-resolution respirometry]]. | |||
|description= | Β | ||
|info=[[ | [http://www.oroboros.at/index.php?oxygraph-2k Two-chamber high-resolution respirometer] for monitoring oxygen consumption with small amounts of biological material, developed by [[OROBOROS INSTRUMENTS]] in cooperation with [http://www.wgt.at WGT], produced in Austria by WGT, and distributed world-wide by OROBOROS INSTRUMENTS. | ||
|product id=20000-01 | |||
|product type=O2k | |||
|info=[http://www.oroboros.at/index.php?o2k-core www.oroboros.at], [[Gnaiger_2008_POS]] | |||
|product image=[[File:O2k-Core.jpg|300px|link=]] | |||
}} | }} | ||
== O2k-Core == | |||
| | Β | ||
The '''O2k-Core''' does not include, but fully supports and is required for the O2kβModules: | |||
::* [[O2k-Fluorescence Module]] | |||
::* O2k-MultiSensor Modules: [[O2k-TPP+ and Ca2+ Electrode Module (ISE)]], [[O2k-pH Electrode Module]], [[O2k-NO MultiSensor Stoppers]] | |||
::* [[TIP2k|Titration-Injection microPump TIP2k]] | |||
Β | |||
The '''O2k-Core''' is a complete experimental system<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000β’ or Win XPβ’.</ref> ready for standard experiments on high-resolution respirometry.Β The O2k-Core consists of the following components: | |||
:1 Peltier thermostat (2 to 47 Β°C; Β±0.001 Β°C) | |||
:2 [[O2k-Chamber|Duran glass chambers]] | |||
:2 [[Polarographic oxygen sensor]]s (POS) | |||
:2 Amperometric POS channels with variable polarization voltage | |||
:2 [[Stirrer bar PVDF 15x6 mm|PVDF stirrers]] and electromagnetic control | |||
:1 Barometric pressure transducer | |||
:1 DatLab 4 (Windowsβ’) data acquision and analysis (USB-stick) | |||
:1 Registration fee is waived for an [http://www.oroboros.at/index.php?nextcourse O2k-Workshop] | |||
:Β World-wide delivery, shipment, insurance, packing and handling included. | |||
Β | |||
::* 2 Potentiometric channels for ion sensitive electrodes (ISE: TPP+, Ca2+; pH), providing the basis for add-on of the [[O2k-MultiSensor Module]]s | |||
::* 2 Amperometric channels with variable polarization voltage, providing the basis for add-on of the [[O2k-Fluorescence Module]] or NO (H<sub>2</sub>S) sensors. | |||
Β | |||
'''O2k-Core Accessories''' are included: | |||
Β | |||
:1 [[O2k-Accessory box]] for POS service, spare membranes | |||
:1 [[Integrated Suction System]] ISS, to remove medium from the O2k-chamber, stainless steel housing with suction pump, 2-liter waste bottle | |||
:6 [[Hamilton syringe 10 mm3 51/0.13 mm|Titration microsyringes 10 mm<sup>3</sup>]] | |||
:6 [[Hamilton syringe 25 mm3 51/0.15 mm|Titration microsyringes 25 mm<sup>3</sup>]] | |||
:2 [[Hamilton syringe 50 mm3 51/0.15 mm|Titration microsyringes 50 mm<sup>3</sup>]] | |||
:3 [[Spare plunger 10 mm3|Spare plungers for 10 mm<sup>3</sup> syringe]] | |||
Β | |||
'''Notes''' | |||
Β | |||
<references/> |
Revision as of 20:13, 3 January 2012
Startup O2k-Respirometer
Description | OROBOROS Oxygraph-2k Core (O2k-Core) is the complete experimental system for high-resolution respirometry.
Two-chamber high-resolution respirometer for monitoring oxygen consumption with small amounts of biological material, developed by OROBOROS INSTRUMENTS in cooperation with WGT, produced in Austria by WGT, and distributed world-wide by OROBOROS INSTRUMENTS. |
---|---|
Product ID | 20000-01 |
Type | O2k |
Link | www.oroboros.at, Gnaiger_2008_POS |
Image |
O2k-Core
The O2k-Core does not include, but fully supports and is required for the O2kβModules:
The O2k-Core is a complete experimental system[1] ready for standard experiments on high-resolution respirometry. The O2k-Core consists of the following components:
- 1 Peltier thermostat (2 to 47 Β°C; Β±0.001 Β°C)
- 2 Duran glass chambers
- 2 Polarographic oxygen sensors (POS)
- 2 Amperometric POS channels with variable polarization voltage
- 2 PVDF stirrers and electromagnetic control
- 1 Barometric pressure transducer
- 1 DatLab 4 (Windowsβ’) data acquision and analysis (USB-stick)
- 1 Registration fee is waived for an O2k-Workshop
- World-wide delivery, shipment, insurance, packing and handling included.
- 2 Potentiometric channels for ion sensitive electrodes (ISE: TPP+, Ca2+; pH), providing the basis for add-on of the O2k-MultiSensor Modules
- 2 Amperometric channels with variable polarization voltage, providing the basis for add-on of the O2k-Fluorescence Module or NO (H2S) sensors.
O2k-Core Accessories are included:
- 1 O2k-Accessory box for POS service, spare membranes
- 1 Integrated Suction System ISS, to remove medium from the O2k-chamber, stainless steel housing with suction pump, 2-liter waste bottle
- 6 Titration microsyringes 10 mm3
- 6 Titration microsyringes 25 mm3
- 2 Titration microsyringes 50 mm3
- 3 Spare plungers for 10 mm3 syringe
Notes
- β A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000β’ or Win XPβ’.