Startup O2k-Respirometer: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Product | {{Product | ||
|description=The '''O2k-Core''' ('''OROBOROS Oxygraph-2k Core''') is the complete experimental system for [[high-resolution respirometry]], supporting all add-on O2k-Modules of the [[Oxygraph-2k]]. | |description=The '''O2k-Core''' ('''OROBOROS Oxygraph-2k Core''') is the complete experimental system for [[high-resolution respirometry]], supporting all add-on O2k-Modules of the [[Oxygraph-2k]]. | ||
|product id=20000-01 | |product id=20000-01 | ||
|product type=O2k, O2k-Module, O2k-Core Set | |product type=O2k, O2k-Module, O2k-Core Set | ||
|info=[http://www.oroboros.at/?Oxygraph-2k @OROBOROS], [[Gnaiger_2008_POS]] | |info=[[Oxygraph-2k]], [http://www.oroboros.at/?Oxygraph-2k @OROBOROS], [[Gnaiger_2008_POS]] | ||
|product image=[[File:O2k-Core.jpg|300px|link=]] | |product image=[[File:O2k-Core.jpg|300px|link=]] | ||
}} | }} | ||
The '''O2k-Core'''<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000™ or Win XP™.</ref> does not include, but fully supports and is required for the add-on Modules of the [[Oxygraph-2k]], such as the [[Titration-Injection microPump|TIP2k]], [[O2k-Fluorescence Module]], [[O2k-TPP+ and Ca2+ Electrode Module (ISE)]], [[O2k-pH Electrode Module]], [[O2k-NO MultiSensor Stoppers]]. | |||
The '''O2k-Core'''<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000™ or Win XP™.</ref> does not include, but fully supports and is required for the add-on Modules of the [[Oxygraph-2k]] | |||
<references/> | <references/> | ||
== '''List of Components: O2k-Core''' == | == '''List of Components: O2k-Core''' == |
Revision as of 11:20, 15 January 2012
Startup O2k-Respirometer
Description | The O2k-Core (OROBOROS Oxygraph-2k Core) is the complete experimental system for high-resolution respirometry, supporting all add-on O2k-Modules of the Oxygraph-2k. |
---|---|
Product ID | 20000-01 |
Type | O2k, O2k-Module, O2k-Core Set"O2k-Core Set" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property. |
Link | Oxygraph-2k, @OROBOROS, Gnaiger_2008_POS |
Image |
The O2k-Core[1] does not include, but fully supports and is required for the add-on Modules of the Oxygraph-2k, such as the TIP2k, O2k-Fluorescence Module, O2k-TPP+ and Ca2+ Electrode Module (ISE), O2k-pH Electrode Module, O2k-NO MultiSensor Stoppers.
- ↑ A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000™ or Win XP™.
List of Components: O2k-Core
The query description has an empty condition.