O2k-Manual: Difference between revisions
From Bioblast
No edit summary |
Tindle Lisa (talk | contribs) No edit summary ย |
||
(83 intermediate revisions by 11 users not shown) | |||
Line 1: | Line 1: | ||
{{ | {{Template:OROBOROS support page name}} | ||
[[File:O2k-Manual.jpg| | {{NextGen-O2k H2020-support}} | ||
[[File:O2k-Manual.jpg|right|200px|O2k-Manual]] | |||
The '''O2k-Manual''' helps beginners and experienced users. Context sensitive help is provided in the '''[[MitoPedia:_DatLab|DatLab software]]'''. | |||
<br>ย ย | |||
::ยป Polarographic oxygen sensors: calibration, accuracy and quality control SOP ยป [[MiPNet06.03_POS-calibration-SOP|MiPNet06.03 POS-calibration-SOP]] | |||
{{#ask:[[Category:Publications]] [[Instrument and method::O2k-Manual]] | ::::ยป Instrumental O<sub>2</sub> background correction, accuracy of oxygen flux and SOP ยป [[MiPNet14.06_Instrumental_O2_background|MiPNet14.06 Instrumental O2 background]]ย ย ย | ||
<br> | |||
ย | |||
__TOC__ | |||
<br> | |||
ย | |||
== NextGen-O2k manual: Series XBย [[File:NextGen-O2k All-in-one 2023.jpg|150px|NextGen-O2k all-in-one]] == | |||
{{#ask:[[Category:Publications]] [[Instrument and method::NextGen-O2k]] [[Instrument and method::O2k-Manual]][[Additional label::NextGen-O2k Series XB manual]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=ascending | |||
|offset=0 | |||
}} | |||
<br> | |||
== O2k manual: Series J == | |||
{{#ask:[[Category:Publications]] [[Additional label::O2k Series J Manual]] | |||
| mainlabel=Chapter | | mainlabel=Chapter | ||
|?Has | |?Has info=View | ||
|? | |?Has title=Section | ||
|?Was published in year=Last update | |?Was published in year=Last update | ||
|format=broadtable | |format=broadtable | ||
|limit=500 | |limit=500 | ||
|sort= | |||
|order=descending | |||
|offset=0 | |||
}} | |||
<br><br> | |||
== O2k-SOP and Quality Control manuals [[File:O2k-QCS.jpg|240px|QC]] ==ย | |||
{{#ask:[[Category:Publications]] [[Instrument and method::O2k-Manual]] [[Additional label::O2k-SOP]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Topic | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=5000 | |||
|offset=0 | |||
|sort=Was published in year | |sort=Was published in year | ||
|order=descending | |order=descending | ||
}} | |||
<br> | |||
== O2k-Module manuals [[File:TPP new.jpg|130px|O2k-TPP+ ISE-Module]] == | |||
{{#ask:[[Category:Publications]] [[Instrument and method::O2k-Manual]] [[Additional label::O2k-Module]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=ascending | |||
|offset=0 | |||
}} | |||
<br> | |||
== Auxiliary HRR-Tools manuals [[File:Oxia.png|100px|Oxia]] == | |||
{{#ask:[[Category:Publications]] [[Instrument and method::O2k-Manual]] [[Additional label::Auxiliary]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=ascending | |||
|offset=0 | |||
}} | |||
<br> | |||
== Data analysis with DatLab [[File:DatLab icon.jpg|100px|DatLab]] == | |||
<div class="mw-collapsible-content"> | |||
{{#ask:[[Category:Publications]] [[Additional label::DL7.4]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=ascending | |||
|offset=0 | |||
}} | |||
</div> | |||
</div> | |||
== Previous O2k-Series manuals == | |||
[[File:Questions.jpg|left|40px]] | |||
<br /> | |||
[[File:Expand.png|right|45px |Click to expand or collaps]] | |||
<div class="toccolours mw-collapsible mw-collapsed"> | |||
=== NextGen-O2k Series XA manual === | |||
<div class="mw-collapsible-content"> | |||
{{#ask:[[Category:Publications]] [[Instrument and method::NextGen-O2k]] [[Instrument and method::O2k-Manual]][[Additional label::NextGen-O2k-Manual]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=ascending | |||
|offset=0 | |||
}} | |||
[[File:Questions.jpg|left|40px]] | |||
<br /> | |||
</div> | |||
</div> | |||
[[File:Expand.png|right|45px |Click to expand or collaps]] | |||
<div class="toccolours mw-collapsible mw-collapsed"> | |||
=== O2k-FluoRespirometer manual: Series H - I === | |||
<div class="mw-collapsible-content"> | |||
{{#ask:[[Category:Publications]] [[Additional label::O2k-FluoRespirometer]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=descending | |||
|offset=0 | |||
}} | |||
<br><br> | |||
[[File:Questions.jpg|left|40px]] | |||
<br /> | |||
</div> | |||
</div> | |||
[[File:Expand.png|right|45px |Click to expand or collaps]] | |||
<div class="toccolours mw-collapsible mw-collapsed"> | |||
=== O2k-Respirometer (Series A - Series G); DatLab 5 and 6 === | |||
<div class="mw-collapsible-content"> | |||
{{#ask:[[Category:Publications]] [[Instrument and method::O2k-Manual]] [[Additional label::Archive]] | |||
| mainlabel=Chapter | |||
|?Has info=View | |||
|?Has title=Section | |||
|?Was published in year=Last update | |||
|format=broadtable | |||
|limit=500 | |||
|sort= | |||
|order=ascending | |||
|offset=0 | |offset=0 | ||
}} | }} | ||
</div> | |||
</div> | |||
[[Image:PlayVideo.jpg|left|60px|link=http://wiki.oroboros.at/index.php/O2k-Videosupport |O2k-Videosupport]] | |||
<big><big>'''O2k-Videosupport'''</big></big> | |||
:: | ::::ยป '''[[O2k-Videosupport]]''' | ||
Latest revision as of 15:18, 18 October 2023
O2k-Manual |
The O2k-Manual helps beginners and experienced users. Context sensitive help is provided in the DatLab software.
- ยป Polarographic oxygen sensors: calibration, accuracy and quality control SOP ยป MiPNet06.03 POS-calibration-SOP
- ยป Instrumental O2 background correction, accuracy of oxygen flux and SOP ยป MiPNet14.06 Instrumental O2 background
- ยป Polarographic oxygen sensors: calibration, accuracy and quality control SOP ยป MiPNet06.03 POS-calibration-SOP
NextGen-O2k manual: Series XB
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet28.07 NextGen-O2k Series XB manual | ยป Versions | NextGen-O2k Series XB manual | 2023-10-19 |
O2k manual: Series J
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet28.08 Oroboros O2k Series J manual | ยป Versions | Oroboros O2k Series J manual | 2023-10-19 |
O2k-SOP and Quality Control manuals
Chapter | View | Topic | Last update |
---|---|---|---|
MiPNet14.06 Instrumental O2 background | ยป Versions | O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. | 2023-10-19 |
MiPNet28.10 SmartPOS-service | ยป Versions | SmartPOS: Service | 2023-09-29 |
MiPNet19.14 SOP Hamilton microsyringes | ยป Versions | SOP for manual O2k-titrations with Hamilton microsyringes. | 2023-09-28 |
MiPNet19.03 O2k-cleaning and ISS | ยป Versions | O2k-Chamber cleaning SOP and Integrated Suction System (ISS). | 2023-03-14 |
MiPNet06.03 POS-calibration-SOP | ยป Versions | O2k Quality Control 1: Polarographic oxygen sensors and accuracy of calibration. | 2023-02-06 |
MiPNet08.16 pH calibration | ยป Versions | Laboratory protocol: pH measurement and temperature dependence of pH. | 2022-03-01 |
MiPNet19.18B POS-service | ยปVersions | Service of the polarographic oxygen sensor OroboPOS. | 2021-06-23 |
MiPNet20.04 O2k-checklist | ยป Versions | O2k-checklist: get started with an O2k-experiment. | 2021-03-12 |
MiPNet07.08 User information | ยป Versions | O2k-Manual: user information. PLEASE STUDY THIS MANUAL. | 2017-11-03 |
MiPNet06.06 Chemical O2 background | ยป Versions | Oxygraph assay of cytochrome c oxidase activity: chemical background correction. | 2015-04-27 |
O2k-Module manuals
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet12.10 TIP2k-manual | ยปVersions | Titration-Injection microPump TIP2k manual. | 2021-07-08 |
MiPNet15.03 O2k-MultiSensor-ISE | ยปVersions | O2k-MultiSensor system with ion selective electrodes (ISE). | 2021-08-02 |
MiPNet15.05 NO-manual | ยปVersions | O2k-MultiSensor system with amperometric sensors: NO, H2S, H2O2. | 2016-04-21 |
MiPNet23.15 O2k-pH ISE-Module | Measurement of proton flux with the O2k-pH ISE-Module. | 2018-09-08 | |
MiPNet24.12 NextGen-O2k: Q-Module | ยป Versions | NextGen-O2k: Q-Module manual | 2021-10-29 |
MiPNet24.14 O2k-sV-Module manual | ยปVersions | O2k-sV-Module manual. | 2020-03-17 |
MiPNet24.16 DatLab8.0: CV-Module | ยปVersions | DatLab8.0: Cyclic voltammetry manual | 2021-10-28 |
MiPNet26.11 NextGen-O2k: PB-Module | ยป Versions | NextGen-O2k: PB-Module manual | 2021-10-29 |
MiPNet26.12 NextGen-O2k: NADH-Module | ยป Versions | NextGen-O2k: NADH-Module manual | 2022-05-17 |
MiPNet28.09 O2k-Fluo Smart-Module manual | ยป Versions | O2k-Fluo Smart-Module manual | 2023-09-25 |
Auxiliary HRR-Tools manuals
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet17.02 PBI-Shredder manual | ยป Versions | PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. | 2015-06-19 |
MiPNet26.14 Oxia | ยป Versions | Oxia - HyperOxia to HypOxia. | 2022-10-31 |
MiPNet27.07 Sample Holder | ยป Versions | Sample Holder. | 2022-08-09 |
Data analysis with DatLab
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet24.06 Oxygen flux analysis - DatLab 7.4 | ยป Versions | Oxygen flux analysis with DatLab 7.4. | 2020-04-16 |
MiPNet24.08 Safranin Analysis Template | ยป Versions | Excel template for safranin data analysis. | 2020-05-13 |
MiPNet24.09 Data analysis of mt-membrane potential | ยป Versions | Data analysis of mt-membrane potential. | 2021-09-16 |
MiPNet24.10 H2O2 flux analysis | ยปVersions | Hydrogen peroxide flux analysis using Amplex UltraRed assay in MiR05-Kit with DatLab 7.4 | 2021-10-22 |
MiPNet24.11 mtMP calculation | ยป Versions | Mitochondrial membrane potential calculation | 2019-08-05 |
MiPNet26.06 DatLab 7: Guide | ยปVersions | DatLab-guide through the menus. | 2021-06-02 |
MiPNet26.10 MgG data analysis | ยปVersions | Measurement of mitochondrial ATP production using Magnesium Green: DL-Protocols and data analysis with DatLab 7.4 | 2021-09-16 |
Previous O2k-Series manuals
NextGen-O2k Series XA manual
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet26.13 NextGen-O2k manual | ยป Versions | NextGen-O2k manual | 2022-07-25 |
O2k-FluoRespirometer manual: Series H - I
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet22.11 O2k-FluoRespirometer manual | ยป Versions | O2k-FluoRespirometer manual. | 2023-03-14 |
O2k-Respirometer (Series A - Series G); DatLab 5 and 6
Chapter | View | Section | Last update |
---|---|---|---|
MiPNet17.05 O2k-Fluo LED2-Module | ยปVersions | O2k-Fluo LED2-Module. | 2021-06-22 |
MiPNet19.01 O2k-Core Manual Series F DatLab 5 | ยปVersions | O2k-Core Manual - up to O2k-Series F and DatLab 5. | 2014-03 |
MiPNet19.18 O2k-Series G Core manual | ยปVersions | O2k-Core manual contents. | 2016-08-08 |
MiPNet19.18A O2k-Series G: Start | ยป Versions | Oxygraph-2k: start high-resolution respirometry. | 2016-08-08 |
MiPNet19.18C DatLab 6: Guide | ยปVersions | DatLab-guide through the menus. | 2016-08-24 |
MiPNet19.18E O2 flux analysis - DatLab 6 | ยปVersions | Oxygen flux analysis: DatLab real-time. | 2016-08-08 |
O2k-Videosupport