Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "E-P control efficiency"

From Bioblast
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=''j<sub>E-P</sub>'', ''CCF<sub>E-P</sub>''
|abbr=''Ex<sub>P</sub>/E''
|description=The '''''E-P'' coupling control factor''', ''j<sub>E-P</sub>'' = (''E-P'')/''E'', is the '''apparent ETS excess capacity over ''P'''''; 0.0 for zero excess capacity when ''P''=''E''. The [[OXPHOS]] state of mt-preparations is stimulated to [[ETS]] by [[uncoupler]] titration. ''j<sub>E-P</sub>'' is zero when the phosphorylation system does not exert any control over OXPHOS capacity (''P''=''E'') and increases with increasing control of the phosphorylation system over OXPHOS capacity in a constant substrate state.
|description=The apparent '''ETS excess factor over ''P''''' (''E-P'' coupling control factor), ''Ex<sub>P</sub>/E'' = (''E-P'')/''E'', is an expression of the relative limitation of [[OXPHOS capacity]] by the capacity of the [[phosphorylation system]]. ''Ex<sub>P</sub>/E'' = 0.0 when OXPHOS is not limited by the phosphorylation system at zero ETS excess capacity, ''P''=''E'', when the phosphorylation system does not exert any control over OXPHOS capacity. ''Ex<sub>P</sub>/E'' increases with increasing control of the phosphorylation system over OXPHOS capacity. ''Ex<sub>P</sub>/E'' = 1 at the limit of zero phosphorylation capacity. The [[OXPHOS]] state of mt-preparations is stimulated to [[ETS]] by [[uncoupler]] titration.
|info=[[Flux control factor]]
|info=[[Flux control factor]]
}}
}}
Line 10: Line 10:
|mitopedia topic=Respiratory control ratio
|mitopedia topic=Respiratory control ratio
}}
}}
== Biochemical coupling efficiency: from 0 to <1 ==
== Compare ==
* [[Phosphorylation system control ratio]]
* ''More details:'' [[Biochemical coupling efficiency]]
* ''More details:'' [[Biochemical coupling efficiency]]
* Compare [[OXPHOS control ratio]] per ETS (phosphorylation system control ratio)





Revision as of 12:58, 9 August 2014


high-resolution terminology - matching measurements at high-resolution


E-P control efficiency

Description

The apparent ETS excess factor over P (E-P coupling control factor), ExP/E = (E-P)/E, is an expression of the relative limitation of OXPHOS capacity by the capacity of the phosphorylation system. ExP/E = 0.0 when OXPHOS is not limited by the phosphorylation system at zero ETS excess capacity, P=E, when the phosphorylation system does not exert any control over OXPHOS capacity. ExP/E increases with increasing control of the phosphorylation system over OXPHOS capacity. ExP/E = 1 at the limit of zero phosphorylation capacity. The OXPHOS state of mt-preparations is stimulated to ETS by uncoupler titration.

Abbreviation: ExP/E

Reference: Flux control factor


MitoPedia methods: Respirometry 


MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 

Compare


List of publications: OXPHOS and ETS