Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "E-P control efficiency"

From Bioblast
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=''Ex<sub>P</sub>/E''
|abbr=''j<sub>ExP</sub>''
|description=The apparent '''ETS excess factor over ''P''''' (''E-P'' coupling control factor), ''Ex<sub>P</sub>/E'' = (''E-P'')/''E'', is an expression of the relative limitation of [[OXPHOS capacity]] by the capacity of the [[phosphorylation system]]. ''Ex<sub>P</sub>/E'' = 0.0 when OXPHOS is not limited by the phosphorylation system at zero ETS excess capacity, ''P''=''E'', when the phosphorylation system does not exert any control over OXPHOS capacity. ''Ex<sub>P</sub>/E'' increases with increasing control of the phosphorylation system over OXPHOS capacity. ''Ex<sub>P</sub>/E'' = 1 at the limit of zero phosphorylation capacity. The [[OXPHOS]] state of mt-preparations is stimulated to [[ETS]] by [[uncoupler]] titration.
|description=The apparent '''ETS excess factor over ''P''''' (''E-P'' coupling control factor), ''j<sub>ExP</sub>'' = (''E-P'')/''E'' = 1-''P/E'', is an expression of the relative limitation of [[OXPHOS capacity]] by the capacity of the [[phosphorylation system]]. ''j<sub>ExP</sub>'' = 0.0 when OXPHOS is not limited by the phosphorylation system at zero ETS excess capacity, ''P''=''E'', when the phosphorylation system does not exert any control over OXPHOS capacity. ''j<sub>ExP</sub>'' increases with increasing control of the phosphorylation system over OXPHOS capacity. ''j<sub>ExP</sub>'' = 1 at the limit of zero phosphorylation capacity. The [[OXPHOS]] state of mt-preparations is stimulated to [[ETS]] by [[uncoupler]] titration.
|info=[[Flux control factor]]
|info=[[Flux control factor]]
}}
}}
Line 12: Line 12:
== Compare ==
== Compare ==
* [[Phosphorylation system control ratio]]
* [[Phosphorylation system control ratio]]
* ''More details:'' [[Biochemical coupling efficiency]]
* ''More details:'' [[ETS coupling efficiency]]





Revision as of 22:08, 25 August 2014


high-resolution terminology - matching measurements at high-resolution


E-P control efficiency

Description

The apparent ETS excess factor over P (E-P coupling control factor), jExP = (E-P)/E = 1-P/E, is an expression of the relative limitation of OXPHOS capacity by the capacity of the phosphorylation system. jExP = 0.0 when OXPHOS is not limited by the phosphorylation system at zero ETS excess capacity, P=E, when the phosphorylation system does not exert any control over OXPHOS capacity. jExP increases with increasing control of the phosphorylation system over OXPHOS capacity. jExP = 1 at the limit of zero phosphorylation capacity. The OXPHOS state of mt-preparations is stimulated to ETS by uncoupler titration.

Abbreviation: jExP

Reference: Flux control factor


MitoPedia methods: Respirometry 


MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 

Compare


List of publications: OXPHOS and ETS