|abbr= | |abbr= | ||
|description=[[Image:Oxia.png|180px|right]]'''Oxia - HyperOxia to HypOxia''': The Oxia generates gaseous [[oxygen]] and [[hydrogen]] by electrolysis of water using a proton exchange membrane (PEM). O<sub>2</sub> and H<sub>2</sub> gas can be used to control the O<sub>2</sub> regime in the Oroboros O2k ([[Setting_the_oxygen_concentration]]). Low oxygen concentrations (<50 ยตM) are used to mimic tissue [[normoxia]] or [[hypoxia]]. Hyperoxic conditions above air saturation (250-600 ยตM O<sub>2</sub>) are routinely used for high-resolution respirometry of [[permeabilized muscle fibers]] or to induce oxidative stress in cells and [[mitochondrial preparations]]. | |description=[[Image:Oxia.png|180px|right]]'''Oxia - HyperOxia to HypOxia''': The Oxia generates gaseous [[oxygen]] and [[hydrogen]] by electrolysis of water using a proton exchange membrane (PEM). O<sub>2</sub> and H<sub>2</sub> gas can be used to control the O<sub>2</sub> regime in the Oroboros O2k ([[Setting_the_oxygen_concentration]]) using the [[Syringe\10 mL\Gas-Injection |10 mL Gas-Injection Syringes]]. Low oxygen concentrations (<50 ยตM) are used to mimic tissue [[normoxia]] or [[hypoxia]]. Hyperoxic conditions above air saturation (250-600 ยตM O<sub>2</sub>) are routinely used for high-resolution respirometry of [[permeabilized muscle fibers]] or to induce oxidative stress in cells and [[mitochondrial preparations]]. | ||
|info= [https://www.oroboros.at/index.php/product/oxia/'''Product details and purchasing information'''] | |info= [https://www.oroboros.at/index.php/product/oxia/'''Product details and purchasing information'''] | ||
}} | }} | ||
== Award winning innovation == | |||
::::ยป [https://opensea.io/assets/ethereum/0x56ad6b0ef013967fd6a1d1522ef437968827a1e8/3 '''CLUSTER AWARD 2022 Life Sciences Standortagentur Tirol'''] | |||
::::ยป [https://www.oroboros.at/index.php/about-us/#awards '''Awards'''] | |||
== Additional resources == | == Additional resources == | ||
::::ยป [[MiPNet26.14 Oxia]] | ::::ยป [[MiPNet26.14 Oxia]] | ||
::::ยป [https://wiki.oroboros.at/images/f/fa/Oxia_CB-Certification.pdf CB-Certification] | ::::ยป [https://wiki.oroboros.at/images/f/fa/Oxia_CB-Certification.pdf CB-Certification] | ||
::::ยป [[Oxygen]] ย | ::::ยป [[Oxygen]] ย | ||
::::ยป [[Hydrogen]] | ::::ยป [[Hydrogen]] ย | ||
::::ยป [[Syringe\10 mL\Gas-Injection]] | |||
ย | |||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |||
}} |
Latest revision as of 16:38, 3 August 2023
Oxia |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Oxia - HyperOxia to HypOxia: The Oxia generates gaseous oxygen and hydrogen by electrolysis of water using a proton exchange membrane (PEM). O2 and H2 gas can be used to control the O2 regime in the Oroboros O2k (Setting_the_oxygen_concentration) using the 10 mL Gas-Injection Syringes. Low oxygen concentrations (<50 ยตM) are used to mimic tissue normoxia or hypoxia. Hyperoxic conditions above air saturation (250-600 ยตM O2) are routinely used for high-resolution respirometry of permeabilized muscle fibers or to induce oxidative stress in cells and mitochondrial preparations.
Reference: Product details and purchasing information
Award winning innovation
Additional resources
- ยป MiPNet26.14 Oxia
- ยป CB-Certification
- ยป Oxygen
- ยป Hydrogen
- ยป Syringe\10 mL\Gas-Injection