|description=The '''O2k signal line''' is underneath the [[O2k status line]]. It shows, depending on the [[O2k series]], on the left side the O2k number, the time of the experiment, the oxygen raw signal of each chamber, the [[block temperature]], the [[barometric pressure]], the Peltier power, the recorded amperometric and potentiometric raw signal, the enviromental (room) temperature and the signal from the external temperature sensor. On the right side of the O2k signal line the current [[user]], the DatLab version and the O2k serial number are displayed.
{{MitoPedia without banner
|info=[[MiPNet19.18A O2k-Start]]
|description=The '''O2k signal line''' is underneath the [[O2k status line]]. It shows, depending on the [[O2k series]], on the left side the O2k number, the time of the experiment, the oxygen raw signal of each chamber, the [[block temperature]], the [[barometric pressure]], the Peltier power, the recorded amperometric and potentiometric raw signal, the enviromental (room) temperature and the signal from internal sensors recording the humidity and temperature of the electronics. On the right side of the O2k signal line the current [[User code - DatLab|user]], the DatLab version and the [[O2k serial number]] are displayed.
|info=[[MiPNet22.11 O2k-FluoRespirometer manual]]
}}
}}
{{MitoPedia concepts}}
[[File:Series I status line.png|850px]]
{{MitoPedia methods}}
ย 
ย 
{{Template:Keywords: Oxygen signal}}
ย 
{{MitoPedia O2k and high-resolution respirometry
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=DatLab
|mitopedia O2k and high-resolution respirometry=DatLab
}}
}}
{{MitoPedia topics}}
[[File:DatLab signal status line.JPG|850px]]

Latest revision as of 09:11, 5 April 2022


                  


O2k-Open Support

O2k signal line



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

[[Description::The O2k signal line is underneath the O2k status line. It shows, depending on the O2k series, on the left side the O2k number, the time of the experiment, the oxygen raw signal of each chamber, the block temperature, the barometric pressure, the Peltier power, the recorded amperometric and potentiometric raw signal, the enviromental (room) temperature and the signal from internal sensors recording the humidity and temperature of the electronics. On the right side of the O2k signal line the current user, the DatLab version and the O2k serial number are displayed.]]


Reference: [[Info::MiPNet22.11 O2k-FluoRespirometer manual]]

Series I status line.png



Questions.jpg


Click to expand or collaps
Bioblast links: Oxygen signal - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>



MitoPedia O2k and high-resolution respirometry: DatLab 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.