Octanoylcarnitine: Difference between revisions

From Bioblast
No edit summary
No edit summary
ย 
Line 25: Line 25:
|store at=-20 ยฐC
|store at=-20 ยฐC
|sensitivity=
|sensitivity=
|cas=18822-86-1
|cas=14919-35-8
|h statements=
|h statements=
|h info=
|h info=

Latest revision as of 10:59, 4 April 2024


high-resolution terminology - matching measurements at high-resolution


Octanoylcarnitine

Description

Octanoylcarnitine is a medium-chain fatty acid (octanoic acid: eight-carbon saturated fatty acid) covalently linked to carnitine, frequently applied as a substrate for fatty acid oxidation (FAO) in mitochondrial preparations.

Abbreviation: Oct

Reference: pdf






MitoPedia topics: Substrate and metabolite 

ยป Fatty acid oxidation
ยป Carnitine O-octanoyltransferase

Application in HRR

Oct: Octanoylcarnitine ((ยฑ)-Octanoylcarnitine chloride; C15H30NO4Cl), BioTrend (brand: APExBIO Technology): B6371-50 mg, store at -20 ยฐC, CAS: 14919-35-8, M = 323.86 gยทmol-1
Alternative: TOCRIS Bioscience, Cat. No. 0605, 50 mg, store at RT, desiccate); M = 323.85 gยทmol-1.
General tips: For obtaining a higher solubility, warm the tube at 37 โ„ƒ and shake it in the ultrasonic bath for a while.


Preparation of 100 mM stock solution (dissolved in H2O or DMSO, can differ from batch to batch - check Certificate of Analysis):
  1. Weigh 50 mg of octanoylcarnitine and dissolve in 1543 ยตL H2O or DMSO.
  2. Divide into 0.2 mL portions.
  3. Store at -20 ยฐC.
  • Note 2024-03-26: According to the information provided by the supplier (BioTrend) is the solubility of Octanoylcarnitine in DMSO and H2O comparable ( โ‰ฅ36.9 mg/mL in DMSO; โ‰ฅ18.6 mg/mL in EtOH; โ‰ฅ37.4 mg/mL in H2O), therefore we consider more rational approach to use H2O as a solvent in OROBOROS Lab because of better handling at room temperature. Disadvantage of DMSO: freezing point of +18.55 ยฐC (65.4 ยฐF). When using DMSO as solvent, make sure to bring the stock solution to room temperature before filling the syringe, which is important to avoid blocking the needle.
communicated by Sobotka Ondrej (talk) 17:46, 26 March 2024 (CET)
ยป O2k manual titrations into 2 mL O2k-chamber
  • Titration volume (2-mL O2k-chamber): 10 ยตL using a 25 ยตL Hamilton syringe.
  • Titration volume (0.5-mL O2k-chamber): 2.5 ยตL using a 10 ยตL Hamilton syringe
  • Final concentration: 0.5 mM in MiR05 or MiR06. Optimum Oct concentrations have to be evaluated, particularly in media with BSA concentrations different from MiR05.



Labels:






MitoPedia:FAT4BRAIN 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.